Analytical Study of Control Systems For Power Loss Minimization In 20 kV Medium Voltage Distribution Network at PT PLN (Persero) ULP Balige
Abstrak
A Power losses in medium voltage distribution networks remain a significant concern for utility companies, particularly in developing regions. This study presents an analytical investigation into the role of control systems in minimizing power losses within the 20 kV medium voltage distribution network at PT PLN (Persero) ULP Balige. This paper research focuses on identifying key components contributing to energy losses, such as unbalanced loading, reactive power flow, and suboptimal voltage regulation. A control system approach is analysed through simulations and system performance evaluations, involving the implementation of automatic capacitor bank control, transformer tap changers, and load balancing strategies. Using simulation tools such as ETAP and actual operational data from the Balige, distribution network, the study evaluates system behaviour under various control scenarios. The results show that implementing a responsive and automated control system significantly reduces technical losses, improves power factor, and enhances voltage profile stability across the network. The study concludes that an integrated control strategy tailored to the characteristics of the local network can optimize distribution efficiency and reduce operational costs. This research provides practical recommendations for PT PLN and similar utilities seeking to modernize their distribution infrastructure through smarter control technologies and data-driven planning.
##plugins.generic.usageStats.downloads##
Referensi
Ir. Slamet Suripto, M. ( 2017 ).ELECTRIC POWER SYSTEM.South Ring Road Tamantirto Kasihan Bantul Yogyakarta Indonesia 55183 . No.094.K/DIR/2006, KB (2007).Distribution Transformer Specification Part Three Phase Transformer, 20 kV-400 V and Single Phase Transformer, 20 kV-231 V.TRUNOJOYO STREET, BLOCK MI/135 KEBAYORAN BARU.
Raja Harahap, JN (2022). DISTRIBUTION SUBSTATION CAPACITY STUDY. UDA ENERGY TECHNOLOGY JOURNAL, Vol 11, No. 1, March 2022 ; 34-43,
Sarikin, RC (2019). ANALYSIS OF POWER AND ENERGY LOSS IN DISTRIBUTIO NETWORK AT PT. PLN (Persero) PANAKKUKANG RAYON. JOURNAL OF ELECTRICAL TECHNOLOGY e-ISSN 2656- 0143, 16, 43 - 47.
Sumardi Sadi SPd ST MT1), MA (2014). COMPARATIVE MEASUREMENT WINDINGS ON A 3-PHASE 50 Hz 250 kVA TRANSFORMER. Engineering Journal, Vol. 3 No. 2 December 2014, 67-74. SUSWANTO, D. (2009 ).ELECTRIC POWER DISTRIBUTION SYSTEM.FIELD.
SYAHPUTRA, DR (2021).TRANSMISSION AND DISTRIBUTION OF ELECTRIC POWER. Yogyakarta.
Triyono2, HS (2023). TRANSFORMER EFFICIENCY CALCULATION. ORBITH VOL. 19 NO. 3 November 2023 : 315 – 323,315-323.
Waluyo1, S. d. (2007). CALCULATION OF POWER LOSS IN THE SYSTEM MEDIUM VOLTAGE DISTRIBUTION OVER AIR LINES AND CABLES.EMAS Journal of Science and Technology, Vol. 17, No. 3, August 2007, 17, 168 - 182.
PLN Standard 50 (1997),Distribution Transformer Specifications.
Aris Sampe, 2022, Analysis of Power Losses Due to Load Imbalance At the 20 Kv/380 V Distribution Transformer in the DPR City Feeder, Department of Electrical Engineering, Cenderawasih University, Jayapura.